Tube

Fluoropolymer (FEP) Tube

RoHS2 Compliant

Compared to our SFT tube, we successfully reduced the cost by 44% average. Color;5 colors, Size;12 sizes including Inch O.D.

Bending radius

  • 5Color

Advantages

Compared to our SFT tube, we successfully reduced the cost by 44% average

Extruded from fluoropolymer(FEP) which is excellent in chemical resitance

Best suitable for chemical, food, medical care and semiconductor industries

Extensive service temperature range

Inch size models, perfect to be used with the inch-sized SUS316 compression fitting are prepared

Cleanroom wash/packaging is available

Cleaning and packing in cleanroom ISO class 6 equivalent

Tube overview

Tube color samples

Actual colors may vary due to the different display methods on your computer monitor.

Specifications

SET0420

Fluid medium Air, Water (Conditional *1), Others such as chemicals (Conditional *1)
Max. operating pressure (65%RH at 20º) 2.7MPa (*2)
Max. vacuum -100kPa
Operating temperature range -65~200ºC (No freezing)

Warning

*1) Adhere to the following conditions in case the fluid is water or any liquids

Surge pressure must be controlled lower than max. operating pressure when using water or any liquids as a fluid medium

Tap water in Japan, which is soft water (low mineral content) can be used. Carry out the evaluation under an actual operating condition for using other kind of water

Be sure to place Insert Ring (WR) into the tubing end when the tubing is inserted into Push-in Fitting with water or any liquids oil as a fluid medium

Can be used with a broad range of chemicals but please check the chemical compatibility before use

*2) The value of max. operating pressure is measured at 20ºC at 65%RH. When the tubing is used in different conditions, consider a safety ratio of the pressure with an enough margin, referring to Burst Pressure Curve

SET0425, SET0640

Fluid medium Air, Water (Conditional *1), Others such as chemicals (Conditional *1)
Max. operating pressure (at 20ºC 65%RH) 1.6MPa (*2)
Max. vacuum -100kPa
Operating temperature range -65~200ºC (No freezing)

Warning

*1) Adhere to the following conditions in case the fluid media is water or any liquids

Surge pressure must be controlled lower than max. operating pressure when using water as a fluid medium

Tap water in Japan, which is soft water (low mineral content) can be used. Carry out the evaluation under an actual operating condition for using other kind of water

Be sure to place Insert Ring (WR) into the tubing end when the tubing is inserted into Push-in Fitting with water or any liquids oil as a fluid medium

Can be used with a broad range of chemicals but please check the chemical compatibility before use

*2) The value of max. operating pressure is measured at 20ºC at 65%RH. When the tubing is used in different conditions, consider a safety ratio of the pressure with an enough margin, referring to Burst Pressure Curve

SET0860, SET1075, SET1290, SET1/4, SET3/8, SET1/2

Fluid medium Air, Water (Conditional *1), Others such as chemicals (Conditional *1)
Max. operating pressure (at 20ºC 65%RH) 1.0MPa (*2)
Max. vacuum -100kPa
Operating temperature range -65~200ºC (No freezing)

Warning

*1) Adhere to the following conditions in case the fluid medium is water or any liquids

Tap water in Japan, which is soft water (low mineral content) can be used. Carry out the evaluation under an actual operating condition for using other kind of water

Be sure to place Insert Ring (WR) into the tubing end when the tubing is inserted into Push-in Fitting with water or any liquids oil as a fluid medium

Can be used with a broad range of chemicals but please check the chemical compatibility before use

*2) The value of max. operating pressure is measured at 20ºC at 65%RH. When the tubing is used in different conditions, consider a safety ratio of the pressure with an enough margin, referring to Burst Pressure Curve

SET1080, SET1210, SET1613

Fluid medium Air, Water (Conditional *1), Others such as chemicals (Conditional *1)
Max. operating pressure (at 20ºC 65%RH) 0.7MPa (*2)
Max. vacuum -100kPa
Operating temperature range -65~200ºC (No freezing)

Warning

*1) Adhere to the following conditions in case the fluid medium is water or any liquids

Surge pressure must be controlled lower than max. operating pressure when using water as a fluid medium

Tap water in Japan, which is soft water (low mineral content) can be used. Carry out the evaluation under an actual operating condition for using other kind of water

Be sure to place Insert Ring (WR) into the tubing end when the tubing is inserted into Push-in Fitting with water or any liquids oil as a fluid medium

Can be used with a broad range of chemicals but please check the chemical compatibility before use

*2) The value of max. operating pressure is measured at 20ºC at 65%RH. When the tubing is used in different conditions, consider a safety ratio of the pressure with an enough margin, referring to Burst Pressure Curve

Port size

mm size

O.D.xI.D.(φmm) 4x2, 4x2.5, 6x4, 8x6, 10x7.5, 10x8, 12x9, 12x10, 16x13

Inch size

O.D.xI.D.(φin) 1/4x0.180, 3/8x0.275, 1/2x0.376

*) 4mm O.D.(4x2) is the same as 5/32" O.D.(5/32x0.079), 4mm O.D.(4x2.5) is 5/32" O.D.(5/32x0.098), 8mm O.D. is 5/16" O.D.(5/16x0.236), 16mm O.D. is 5/8" O.D.(5/8x0.512) as well

Type & Price list

mm size

Inch size

Detailed Safety Instructions

Warning

1.In case of using with chemicals, solvents or mixed gases, please check the chemical compatibility before use. Incorrect use could result in breakdown of fittings, fluid leakage or tubing falling off

2.Even though the evaluation on the chemical resistance chart shows positive with FEP material, there is a possibility that problems may occur due to factors such as temperature, pressure or physical action by stress. Before permanent installation, test the equipment with the chemicals under the specific conditions of your application, especially for applications with solvents

3.Avoid using in areas prone to vibrations.

4.For long-term use, it is recommended to use Compression Fittings. Due to material degradation over time, leaks may occur. Perform regular maintenance, and promptly replace the product if any leaks are detected.

Frequently Asked Questions for Tube Series

Inquiries about this product

It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.

The following are frequently asked questions. Please check before making inquiries.