External Vacuum Controller

External Vacuum Controller VNP

RoHS2 Compliant

External Vacuum Controller best suitable for the fields requires space-saving and high speed.

Advantages

Applying direct acting valve does not require compressed air at vacuum supply.

External Vacuum Controller best suitable for the fields requires space-saving and high speed.

Suitable for the application requiring a limited space (body height).

Compact and lightweight.

High speed, yet stable response is realized. (ON/OFF=Max. 5msec)

Direct operated solenoid valve is used for the main valve.

4 types of analog output sensors are selectable.

Analog output type pressure sensor for negative pressure, Separate LED indicator + Analog output type pressure for negative pressure, Analog output type sensor for compound pressure, Separate LED indicator + Analog output type sensor for compound pressure.
Analog output sensor for negative pressure with connector type sensor cable for easy wiring and maintenance.

Specifications

Specifications

Fluid medium Air (JIS B 8392-1:Class1.2.1~2.4.3 compliant), Vacuum
Operating pressure range 0~0.55MPa
Working vacuum range -100~0kPa
Operating temp. range 5~50℃ (No freezing)
Operating humidity range 35~85%RH (No dew condensation)
Protective structure Equivalent to IEC IP40
Vibration/Impact resistance Max. 50m/s2 / Max. 150m/s2
Lubrication Not required
Proof pressure (Air supply circuit) 0.85MPa
Proof pressure (Vacuum circuit) 0.2MPa

* Proof pressure does not indicate the pressure by which products operate normally but the pressure by which products does not break down.

Solenoid valve specifications

Rated voltage DC24V ±10%
Power consumption Startup:2.2W, Retention:0.6W (Power saving circuit)
Surge protection Incorporated
Operation indicator Current application:Green LED ON
Manual operation Not available

Vacuum supply valve specifications

Operation type Direct operation
Valve type Normally closed
Response time (OFF→ON) 5msec
Response time (ON→OFF) 5msec

* The response time is the value in the steady state (at vacuum supply:-100~0kPa, operating temp.:20℃, apply voltage:DC24V±10%).

Blow-off valve specifications

Operation type Direct operation
Valve type Normally closed
Response time (OFF→ON) 5msec
Response time (ON→OFF) 5msec

* The response time is the value in the steady state (at supply air:0.05~0.55MPa, operating temp.:20℃, apply voltage:DC24V±10%).

Blow-off function

Blow-off air rate 0~20L/min[ANR] (at supply pressure 0.5MPa)

* Blow-off air rate varies according to the vacuum port dia. and tube length on vacuum side.

Pressure sensor with LED display specifications (V4NC□:Negative pressure/NPN output)

Fluid medium Air, Non-corrosive/Non-flammable gas
Pressure detection method Diffusion semiconductor pressure sensor
Operating temp. range 0~50℃ (No freezing)
Storage temperature range -20~70℃ (Atmospheric pressure, Humidity 65%RH max.) (No freezing)
Operating humidity range 35~85%RH (No dew condensation)
Vibration proof 100m/s2
Shock resistance 150m/s2
Protective structure Equivalent to IEC IP40
Operating pressure range -100kPa~0kPa
Proof pressure 0.9MPa
Power supply DC12~24V ±10% (including Ripple P to P)
Current consumption 30mA max. (at All LED on, no load with 2 points output)
Display element "-" Sign & 2 digits, 7 segments Red LED
Display frequency 4 times/sec.
Monitor system Overpressure indication, blinking display
Panel lock function On/Off by push-button
Non-display function On/Off by push-button
Indication accuracy ±3%F.S. (0~50℃, at Ta=25℃)
Zero point adjustment Adjustable by zero adjusting mode
Switch output/No. of pressure setting 2 points SW output
Switch output/Output method NPN open collector
Switch output/Switch capacity DC30V 80mA max.
Switch output/Residual voltage 1.2V max. (at load current 80mA)
Switch output/Output mode Separate mode, Window comparator mode (Selection)
Switch output/Pressure setting range -99~0(kPa)
Switch output/Operational indication Output ON:LED ON (SW1:Red/SW2:Green)
Switch output/Temperature characteristics ±5%F.S. (0~50℃, at Ta=25℃)
Switch output/Repeat accuracy ±0.3%F.S.
Switch output/Response time Filter setting at 0msec:5msec, Setting range (Selectable from 0~99msec)
Switch output/Hysteresis adjustment 0~30count
Switch output/Overload protection Equipped
Analog output/No. of pressure setting 1 output
Analog output/Output voltage 1~5V
Analog output/Zero point voltage (0kPa) 1 ±0.06V
Analog output/Voltage with negative pressure applied (-90kPa) 4.6 ±0.06V
Analog output/Output current 1mA (MAX)
Analog output/Linearity ±0.5%F.S.
Analog output/Repeat accuracy ±0.5%F.S.
Analog output/Temperature characteristics 5%F.S. (0~50℃, at Ta=25℃)

Pressure sensor with LED display specifications (V4PC□: Negative pressure / PNP output)

Fluid medium Air, Non-corrosive/Non-flammable gas
Pressure detection method Diffusion semiconductor pressure sensor
Operating temp. range 0~50℃ (No freezing)
Storage temperature range -20~70℃ (Atmospheric pressure, Humidity 65%RH max.) (No freezing)
Operating humidity range 35~85%RH (No dew condensation)
Vibration proof 100m/s2
Shock resistance 150m/s2
Protective structure Equivalent to IEC IP40
Operating pressure range -100kPa~0kPa
Proof pressure 0.9MPa
Power supply DC12~24V ±10% (including Ripple P to P)
Current consumption 30mA max. (at All LED on, no load with 2 points output)
Display element ""-"" Sign & 2 digits, 7 segments Red LED
Display frequency 4 times/sec.
Monitor system Overpressure indication, blinking display
Panel lock function On/Off by push-button
Non-display function On/Off by push-button
Indication accuracy ±3%F.S. (0~50℃, at Ta=25℃)
Zero point adjustment Adjustable by zero adjusting mode
Switch output/No. of pressure setting 2 points SW output
Switch output/Output method PNP open collector
Switch output/Switch capacity DC26.4V 80mA max.
Switch output/Residual voltage 1.2V max. (at load current 80mA)
Switch output/Output mode Separate mode, Window comparator mode (Selection)
Switch output/Pressure setting range -99~0(kPa)
Switch output/Operational indication Output ON:LED ON (SW1:Red/SW2:Green)
Switch output/Temperature characteristics ±5%F.S. (0~50℃, at Ta=25℃)
Switch output/Repeat accuracy ±0.3%F.S.
Switch output/Response time Filter setting at 0msec:5msec, Setting range (Selectable from 0~99msec)
Switch output/Hysteresis adjustment 0~30count
Switch output/Overload protection Not equipped
Analog output/No. of pressure setting 1 output
Analog output/Output voltage 1~5V
Analog output/Zero point voltage (0kPa) 1 ±0.06V
Analog output/Voltage with negative pressure applied (-90kPa) 4.6 ±0.06V
Analog output/Output current 1mA (MAX)
Analog output/Linearity ±0.5%F.S.
Analog output/Repeat accuracy ±0.5%F.S.
Analog output/Temperature characteristics 5%F.S. (0~50℃, at Ta=25℃)

Pressure sensor with LED display specifications (V4RNC□:Compound pressure/NPN output)

Fluid medium Air, Non-corrosive/Non-flammable gas
Pressure detection method Diffusion semiconductor pressure sensor
Operating temp. range 0~50℃ (No freezing)
Storage temperature range -20~70℃ (Atmospheric pressure, Humidity 65%RH max.) (No freezing)
Operating humidity range 35~85%RH (No dew condensation)
Vibration proof 100m/s2
Shock resistance 150m/s2
Protective structure Equivalent to IEC IP40
Operating pressure range -100kPa~300kPa
Proof pressure 1.4MPa
Power supply DC12~24V ±10% (including Ripple P to P)
Current consumption 30mA max. (at All LED on, no load with 2 points output)
Display element ""-"" Sign & 2 digits, 7 segments Red LED
Display frequency 4 times/sec.
Monitor system Overpressure indication, blinking display
Panel lock function On/Off by push-button
Non-display function On/Off by push-button
Indication accuracy ±3%F.S. (0~50℃, at Ta=25℃)
Zero point adjustment Adjustable by zero adjusting mode
Switch output/No. of pressure setting 2 points SW output
Switch output/Output method NPN open collector
Switch output/Switch capacity DC30V 80mA max.
Switch output/Residual voltage 1.2V max. (at load current 80mA)
Switch output/Output mode Separate mode, Window comparator mode (Selection)
Switch output/Pressure setting range -99~0(kPa), 0~0.30(MPa)
Switch output/Operational indication Output ON:LED ON (SW1:Red/SW2:Green)
Switch output/Temperature characteristics ±5%F.S. (0~50℃, at Ta=25℃)
Switch output/Repeat accuracy ±0.3%F.S.
Switch output/Response time Filter setting at 0msec:5msec, Setting range (Selectable from 0~99msec)
Switch output/Hysteresis adjustment 0~30count
Switch output/Overload protection Equipped
Analog output/No. of pressure setting 1 output
Analog output/Output voltage 1~5V
Analog output/Zero point voltage (0kPa) 2 ±0.06V
Analog output/Voltage with negative pressure applied (-90kPa) 1.1 ±0.06V
Analog output/Voltage with max. positive pressure applied 5 ±0.06V
Analog output/Output current 1mA (MAX)
Analog output/Linearity ±0.5%F.S.
Analog output/Repeat accuracy ±0.5%F.S.
Analog output/Temperature characteristics 5%F.S. (0~50℃, at Ta=25℃)

Pressure sensor with LED display specifications (V4RPC□:Compound pressure/PNP output)

Fluid medium Air, Non-corrosive/Non-flammable gas
Pressure detection method Diffusion semiconductor pressure sensor
Operating temp. range 0~50℃ (No freezing)
Storage temperature range -20~70℃ (Atmospheric pressure, Humidity 65%RH max.) (No freezing)
Operating humidity range 35~85%RH (No dew condensation)
Vibration proof 100m/s2
Shock resistance 150m/s2
Protective structure Equivalent to IEC IP40
Operating pressure range -100kPa~300kPa
Proof pressure 1.4MPa
Power supply DC12~24V ±10% (including Ripple P to P)
Current consumption 30mA max. (at All LED on, no load with 2 points output)
Display element ""-"" Sign & 2 digits, 7 segments Red LED
Display frequency 4 times/sec.
Monitor system Overpressure indication, blinking display
Monitor system Overpressure indication, blinking display
Non-display function On/Off by push-button
Indication accuracy ±3%F.S. (0~50℃, at Ta=25℃)
Zero point adjustment Adjustable by zero adjusting mode
Switch output/No. of pressure setting 2 points SW output
Switch output/Output method PNP open collector
Switch output/Switch capacity DC26.4V 80mA max.
Switch output/Residual voltage 1.2V max. (at load current 80mA)
Switch output/Output mode Separate mode, Window comparator mode (Selection)
Switch output/Pressure setting range -99~0(kPa), 0~0.30(MPa)
Switch output/Operational indication Output ON:LED ON (SW1:Red/SW2:Green)
Switch output/Temperature characteristics ±5%F.S. (0~50℃, at Ta=25℃)
Switch output/Repeat accuracy ±0.3%F.S.
Switch output/Response time Filter setting at 0msec:5msec, Setting range (Selectable from 0~99msec)
Switch output/Hysteresis adjustment 0~30count
Switch output/Overload protection Not equipped
Analog output/No. of pressure setting 1 output
Analog output/Output voltage 1~5V
Analog output/Zero point voltage (0kPa) 2 ±0.06V
Analog output/Voltage with negative pressure applied (-90kPa) 1.1 ±0.06V
Analog output/Voltage with max. positive pressure applied 5 ±0.06V
Analog output/Output current 1mA (MAX)
Analog output/Linearity ±0.5%F.S.
Analog output/Repeat accuracy ±0.5%F.S.
Analog output/Temperature characteristics 5%F.S. (0~50℃, at Ta=25℃)

Pressure sensor without LED display specifications (V1C□, 1 analog output for negative pressure)

Wire connection method Connector type
Rated voltage DC10.8~30V (Ripple voltage included)
Current consumption 20mA max. (DC24V no-load)
Pressure detection method Diffusion semiconductor pressure sensor
Operating pressure range -100~0kPa
Proof pressure 1MPa
Storage temperature range -20~70℃ (Atmospheric pressure, Humidity:65%RH max.)
Operating temp. range 0~60℃ (No freezing)
Operating humidity range 30~85%RH (No dew condensation)
Protective structure Equivalent to IEC IP40
Analog output/Output voltage 1~5V
Analog output/Zero point voltage 1 ±0.04V (= at atmospheric)
Analog output/Specified pressure voltage 4.6 ±0.04V(= at -90kPa)
Analog output/Max. rated pressure voltage 5 ±0.04V(= at -100kPa)
Analog output/Linearity ±0.5%F.S. max. (at Ta=25℃)
Analog output/Temperature characteristics ±2%F.S. max. (0~60℃, at Ta=25℃)
Analog output/Output current 0.495mA max. (Load resistance:10kΩ)
Analog output/Output impedance 1kΩ

* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.

Pressure sensor without LED display specifications (R1, 1 analog output for compound pressure)

Wire connection method Grommet type
Rated voltage DC10.8~30V (Ripple voltage included)
Current consumption 20mA max. (DC24V no-load)
Pressure detection method Diffusion semiconductor pressure sensor
Operating pressure range -100~300kPa
Proof pressure 600kPa
Storage temperature range -20~70℃ (Atmospheric pressure, Humidity:65%RH max.)
Operating temp. range -10~60℃ (No freezing)
Operating humidity range 35~85%RH (No dew condensation)
Protective structure Equivalent to IEC IP40
Analog output/Output voltage 1~5V
Analog output/Zero point voltage 1 ±0.1V(= at -100kPa)
Analog output/Max. rated pressure voltage 5 ±0.1V(= at 300kPa)
Analog output/Linearity ±0.5%F.S. max. (at Ta=25℃)
Analog output/Temperature characteristics ±2%F.S. max.
Analog output/Output current 1mA max. (Load resistance:5kΩ)

* Allowable range of the variation of “Zero point voltage”, "Span voltage" and “Pressure setting value” caused by repeated voltage application is ±3%F.S.

Port size

Vacuum port tube dia.

mm size(mm) φ3, φ4

Vacuum supply port tube dia.

Stand-alone type

mm size(mm) φ3, φ4

Manifold type

mm size(mm) φ4, φ6, φ8

Air supply port tube dia. for blow-off air

Stand-alone type

mm size(mm) φ3, φ4

mm size(mm);Manifold type

mm size(mm) φ4, φ6, φ8

Ordering Information

Stand-alone type

Manifold type

Bracket for stand-alone type (option)

Filter element for stand-alone type (Maintenance parts)

Connector cable for analog output type pressure sensor for negative pressure (Maintenance parts)

Connector cable for pressure sensor with LED display (Maintenance parts)

Detailed Safety Instructions

Warning

1.All screws must be tightened to the correct torque referring to the instructions. The tightening torques, for the mounting of the product is given in "How to fix Stand-alone/Manifold type", and for the solenoid valve is given in "How to replace Filter Elements". Failure to tighten to the correct torque may result in air leaks, product detachment and damage to parts of the product.

2.If the product is energized continuously for about 15 minutes or more, the frequency of continuous energizing should not exceed 10 times per day.

3.The solenoid valve of this product uses a current limit circuit, which is a feature that reduces the current value when the coil is kept energized. Do not use in environments subject to vibrations or shocks outside the specifications. It may lead to troubles such as valve malfunction.

Caution

1.This product is not equipped with a vacuum filter. Be sure to use PISCO vacuum filter series together. If a vacuum filter is not used, dust and dirt can accumulate inside the product, causing poor vacuum performance, leaks and malfunctioning of the solenoid valve. (Recommended vacuum filters: VFU series, VFJ series)