Air Preparation

Dry Unit Series

RoHS2 Compliant

Fiber Dry is newly combined to Filter/Mist-Filter or Micromist Filter/Regulator.

Advantages

Fiber Dry is newly combined to Filter/Mist-Filter or Micromist Filter/Regulator.

Direct connection to air source. (For space-saving)

Specifications

Air Filter Manual drain Spec.

Port size Rc1/4, Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.05MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 5μm(Trapping efficiency: 99.99%)
Bowl capacity 30cc

* Based on PISCO measuring condition.

Air Filter Auto drain

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.15MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 5μm(Trapping efficiency: 99.9%)

* Based on PISCO measuring condition.

Mist Filter Manual drain

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.05MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 0.3μm(Trapping efficiency: 99.9%)
Bowl capacity 30cc

* Based on PISCO measuring condition.

Mist Filter Auto drain spec.

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.05MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 0.3μm(Trapping efficiency: 99.9%)

* Based on PISCO measuring condition.

Micromist Filter Manual drain spec.

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.05MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 0.01μm(Trapping efficiency: 99.9%)
Bowl capacity 30cc

* Based on PISCO measuring condition.

Micromist Filter Auto drain spec.

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.15MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 0.01μm(Trapping efficiency: 99.9%)

* Based on PISCO measuring condition.

Fiber Dryer

Fluid medium Air
Operating pressure range Inside of hollow fiber membrane: 0.3~0.85MPa/Outside of hollow fiber membrane: 0~0.05MPa
Fluid medium temp. 0~40℃(No freezing)
Operating temp. range 0~60℃(No freezing)

* When fluid medium other than air is used, contact us for details before using.

Regulator spec.

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Pressure setting range 0.05~0.85MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃

Gauge spec.

Fluid medium Air
Indicated pressure range 0~1.0MPa
Accuracy ±5% F.S.

Digital pressure gauge spec.

Rated pressure range 0.000~1.000MPa
Pressure indication range -0.100~1.000MPa(*1、*2)
Proof pressure 1.5MPa
Fluid medium Air, non-corrosive / non-flammable gas
Battery CR2032 Lithium battery(*4)
Battery life Approx. 3 years (at 5 times indication/day)
Low power indicator included
Battery replacement Yes
Turn-on interval Display turn off after 60 sec.
Sampling rate 2Hz (2 times/sec.)
Repeatability ≦±0.2% F.S.± 1digit
LCD display 7 segments, 3.5 digits
Indicator accuracy ≦±2% F.S.± 1digit(ambient temperature: 25±3℃)
Protective structure IP65(*3)
Ambient temp. range Operation:0~50℃, Storage:-10~60℃(No dew condensation, no freezing)
Ambient humidity range Operation/Storage:35~85%RH (No dew condensation)
Vibration proof Total amplitude 1.5mm or 100m/s²,10Hz-55Hz-10Hz scan for 1minute, Direction of X, Y and Z for 2 hours each
Shock resistance 100m/s², 3 times each in direction of X, Y and Z
Temperature characteristic ±2% F.S. of detected pressure (25℃)

*1 The display at the time of impressing negative pressure will be shown like below.

*2. The range of -0.1 to 0 MPa is outside the guaranteed accuracy range of the display.

*3. Air tube must be inserted into the atmospheric release port to maintain IP65. See below figure.

Pressure Sensor with LCD Dual-display spec.

Rated pressure range 0.000~1.000MPa
Proof pressure 1.5MPa
Fluid medium Air, non-corrosive / non-flammable gas
Power supply source DC12V~24V (Ripple max. ±10%)
Consumption current Less than 40mA (at no-loaded)
Switch output Output type NPN open collector output/PNP open collector output
Switch output Max. load current 125mA
Switch output Max. supply voltage DC30V(NPN open collector output)/DC24V(PNP open collector output)
Switch output Residual voltage Max. 1.5V
Repeatability ≦±0.2% F.S.±1 digit
Hysteresis One point set mode Adjustable(*)
Hysteresis Hysteresis mode Adjustable(*)
Hysteresis Window comparator mode Adjustable(*)
Response time 2.5ms or less(Malfunction protection function:Selection from 25ms, 100ms, 250ms, 500ms, 1000ms, 1500ms)
Overload protection Included
Digital display 3 colors (Red, Green, Orange) indication (Sampling rate: 5 times/sec.)
Display accuracy ≦±2% F.S.±1digit(ambient temperature: at Ta=25±3℃)
Operation indicator Orange 1&2 indicator
Analog output (Voltage output) Output voltage:1~5V±2%F.S. or less (within rated pressure range), Linearity:±1%F.S. or less, Output impedance :1kΩ
Environment proof Protective structure IP40
Environment proof Ambient temp. range Operation : 0~50℃, Storage : -10~60℃ (No dew condensation or freezing)
Environment proof Ambient humidity range Operation/Storage : 35~85%RH (No dew condensation)
Environment proof Voltage proof AC1000V 1 min. (Between the lead wire and the case)
Environment proof Insulation proof Over 50MΩ (DC500V) (Between the lead wire and the case)
Environment proof Vibration resistance Total amplitude 1.5mm or 100m/s² 10Hz-150Hz-10Hz scan for 1 min., 2 hours each direction of X, Y and Z.
Environment proof Shock resistance 100m/s², 3 times each in direction of X, Y and Z
Temperature characteristics Max. ±2% F.S.(at Ta=25ºC, at temp. range 0~ +50℃)
Cable spec. Oil-resistance cable (0.15mm²)

*Hysteresis value is adjustable within 1~8 digits for one point set mode and window comparator mode.

Port size

Tube size

mm size (mm) φ4, φ6, φ8, φ10, φ12, φ16

Thread size

Taper pipe female thread Rc1/4, Rc3/8

Characteristic Graph

Ordering Information

Detailed Safety Instructions

Caution

1.Be sure to adjust the regulator in the direction of increasing pressure, and be sure to push the handle to lock it after adjusting the pressure.

2.Until the supply pressure rises to 0.05MPa for manual drain type and 0.15MPa for auto drain type, air will be discharged from the drain outlet, but this is not a malfunction.. At this timing, turning the drain knob will not stop the air flow. (If it takes a long time for the supply pressure to rise to 0.15MPa, please consult with PISCO.)

3.The drainage knob must be operated with the fingertips.

4.Use nylon tubing with an internal diameter of ø6 mm when piping tubing to the joint of the manual drain cock. The tube should not be bent immediately after the fitting.

5.The joint of the manual drain cock rotates freely and there is no need to remove the tube when draining manually.

6.Refer to the corresponding pages of precautions related to the dual-display digital pressure sensor and digital pressure gauge in the digital catalog.

Frequently Asked Questions for Air Preparation Series

Inquiries about this product

It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.

The following are frequently asked questions. Please check before making inquiries.