Air Preparation

Filter Regulator

RoHS2 Compliant

Combined with a filter and regulator.

Advantages

Combined with a filter and regulator.

The filter removes drain and dust in pipes.

Filtering accuracy :5μm

Handle for regulator is easy locking by push lock type handle.

Three types of attached gauges are available: direct mount type compact pressure gauge, with pressure sensor with LCD dual-display , and digital pressure gauge.

Direct mount type compact pressure gauge with special scale

Pressure indications are readable from the side

A type without a pressure gauge is available.

Specifications

Regulator (Manual drain) Spec.

Port size Rc1/4, Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.05MPa
Pressure setting range 0.05~0.85MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 5μm(Trapping efficiency: 99.99%)
Bowl capacity 30cc

* Based on PISCO measuring condition.

Regulator (Auto drain) spec.

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.15MPa
Pressure setting range 1.5~0.85MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 5μm(Trapping efficiency: 99.9%)

* Based on PISCO measuring condition.

Gauge spec.

Fluid medium Air
Indicated pressure range 0~1.0MPa
Accuracy ±5% F.S.

Digital Pressure Gauge spec.

Rated pressure range 0.000~1.000MPa
Indicated pressure range -0.100~1.000MPa(*1、*2)
Proof pressure 1.5MPa
Fluid medium Air, non-corrosive / non-flammable gas
Battery CR2032 Lithium battery(*4)
Battery life Approx. 3 years (When displayed 5 times per day)
Lowest battery detection function Equipped
Battery replacement Possible
Display time 60 seconds after pressing the button
Display times 2Hz(twice/s)
Repeatability ≦±0.2% F.S. ±1 digit
LCD indicator 7 segments, 3.5 digit
Indication accuracy ±2% F.S. ±1 digit or less ( at Ta=25±3℃)
Protective structure IP65 (*3)
Ambient temp. range Operation : 0~50℃, Storage : -10~60℃ (No dew condensation or freezing)
Ambient humidity range Operation/Storage : 35~85%RH (No dew condensation)
Vibration resistance Total amplitude 1.5mm or 100m/s² 10Hz-55Hz-10Hz scan for 1 min., two hours each direction of X, Y and Z.
shock resistance 100m/s², 3 times each in direction of X, Y and Z
Temperature characteristics Detection pressure of ±2% F.S (at 25℃)

*1. When negative pressure is applied, it is displayed as shown in the figure below.

*2. The range of -0.1 to 0 MPa is outside the guaranteed accuracy range of the display.

*3. Air tube must be inserted into the atmospheric release port to maintain IP65. See below figure.

Pressure Sensor with LCD Dual-display spec.

Rated pressure range 0.000~1.000MPa
Proof pressure 1.5MPa
Fluid medium Air, non-corrosive / non-flammable gas
Power supply DC12V~24V(Ripple max. ±10%)
Current consumption 40mA or less (at No-loaded)
Switch output Switch output NPN open collector output/PNP open collector output
Switch output Max. load current 125mA
Switch output Max. supply voltage DC30V(NPN open collector output)/DC24V(PNP open collector output)
Switch output Residual voltage Max. 1.5V
Repeatability ±0.2% F.S. max. ±1 digit
Hysteresis One point setting mode Adjustable(*)
Hysteresis hysteresis mode Adjustable(*)
Hysteresis Wind comparator mode Adjustable(*)
Response time Max. 2.5ms (Malfunction protection function:Select from 25ms, 100ms, 250ms, 500ms, 1000ms, 1500ms)
Overload protection Equipped
Digital display 3 colors (Red, Green, Orange) indication (Sampling rate: 5 times / 1sec.)
Indication accuracy ±2% F.S. max. ±1 digit( at Ta=25±3℃)
Operation indicator Orange 1&2 indicator
Analog output(Voltage output) Output voltage:1~5V ±2.5% F.S. or less (within rated pressure range), Linearity:±1%F.S. or less, Output impedance :1kΩ
Environment proof Protective structure IP40
Environment proof Ambient temp. range Operation : 0~50℃, Storage : -10~60℃ (No dew condensation or freezing)
Environment proof Ambient humidity range Operation/Storage : 35~85%RH (No dew condensation)
Environment proof Voltage proof AC1000V 1 min. (Between the lead wire and the case)
Environment proof Insulation proof more than 50MΩ(DC500V)(Between the lead wire and the case)
Environment proof Vibration resistance Total amplitude 1.5mm or 100m/s² 10Hz-55Hz-10Hz scan for 1 min., two hours each direction of X, Y and Z.
Environment proof shock resistance 100m/s², 3 times each in direction of X, Y and Z
Temperature characteristics ±2% F.S or less (at 25℃, in temp. Range of 0~50℃)
Cable spec. Oil-resistance cable(0.15mm²)

* Hysteresis is adjustable(1~8 digits) in One point setting mode and Wind comparator mode.

Port size

Thread size

Taper pipe female thread Rc1/4, Rc3/8

Characteristic Graph

Construction

Ordering Information

Detailed Safety Instructions

Caution

1.When the secondary side is released into the atmosphere, sympathetic vibration may occur due to the influence of the flow. Avoid prolonged use with the secondary side open to the atmosphere, as this may cause internal damage and other malfunctions.

2.Be sure to adjust the regulator in the direction of increasing pressure, and be sure to push the handle to lock it after adjusting the pressure.

3.Refer to the corresponding pages of precautions related to the dual-display digital pressure sensor and digital pressure gauge in the digital catalog.

4.Until the supply pressure rises to 0.05MPa for manual drain type and 0.15MPa for auto drain type, air will be discharged from the drain outlet, but this is not a malfunction.. At this timing, turning the drain knob will not stop the air flow. (If it takes a long time for the supply pressure to rise to 0.15MPa, please consult with PISCO.)

5.The drainage knob must be operated with the fingertips.

6.Use nylon tubing with an internal diameter of ø6 mm when piping tubing to the joint of the manual drain cock. The tube should not be bent immediately after the fitting.

7.The joint of the manual drain cock rotates freely and there is no need to remove the tube when draining manually.

Frequently Asked Questions for Air Preparation Series

Inquiries about this product

It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.

The following are frequently asked questions. Please check before making inquiries.