Air Preparation

Filter and Regulator Combination Unit Series

RoHS2 Compliant

Air Filter(Filtering accuracy :5μm), Mist Filter (Filtering accuracy: 0.3μm), Micromist Filter (Filtering accuracy: 0.01μm), Combined regulator.

Advantages

Air Filter(Filtering accuracy :5μm), Mist Filter (Filtering accuracy: 0.3μm), Micromist Filter (Filtering accuracy: 0.01μm), Combined regulator.

Variety of combinations and easy maintenance.

Two drainage methods: Manual or Auto draining

Specifications

Air Filter Manual drain Spec.

Port size Rc1/4, Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.05MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 5μm(Trapping efficiency: 99.99%)
Bowl capacity 30cc

* Based on PISCO measuring condition.

Air filter Auto drain spec.

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.15MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 5μm(Trapping efficiency: 99.9%)

* Based on PISCO measuring condition.

Mist Filter Manual drain

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.05MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 0.3μm(Trapping efficiency: 99.9%)
Bowl capacity 30cc

* Based on PISCO measuring condition.

Mist Filter Auto drain spec.

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.05MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 0.3μm(Trapping efficiency: 99.9%)

* Based on PISCO measuring condition.

Micromist Filter Manual drain spec.

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.05MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 0.01μm(Trapping efficiency: 99.9%)
Bowl capacity 30cc

* Based on PISCO measuring condition.

Micromist Filter Auto drain spec.

Port size Rc1/4、Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Min. operating pressure 0.15MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃
Filtering accuracy(*) 0.01μm(Trapping efficiency: 99.9%)

* Based on PISCO measuring condition.

Regulator spec.

Port size Rc1/4, Rc3/8
Fluid medium Air
Max. operating pressure 1.0MPa
Pressure setting range 0.05MPa~0.85MPa
Pressure resistance 1.5MPa
Operating temp. range 5~50℃

Gauge spec.

Fluid medium Air
Indicated pressure range 0~1.0MPa
Accuracy ±5% F.S.

Digital Pressure Gauge spec.

Rated pressure range 0.000~1.000MPa
Pressure indication range -0.100~1.000MPa(*1、*2)
Proof pressure 1.5MPa
Fluid medium Air, non-corrosive / non-flammable gas
Battery CR2032 Lithium battery(*4)
Battery life Approx. 3 years (at 5 times indication/day)
Low power indicator included
Battery replacement Yes
Turn-on interval Display turn off after 60 sec.
Sampling rate 2Hz (2 times/sec.)
Repeatability ≦±0.2% F.S.± 1digit
LCD display 7 segments, 3.5 digits
Indicator accuracy ≦±2% F.S.± 1digit(ambient temperature: 25±3℃)
Protective structure IP65(*3)
Ambient temp. range Operation:0~50℃, Storage:-10~60℃(No dew condensation, no freezing)
Ambient humidity range Operation/Storage:35~85%RH (No dew condensation)
Vibration proof Total amplitude 1.5mm or 100m/s²,10Hz-55Hz-10Hz scan for 1minute, Direction of X, Y and Z for 2 hours each
Shock resistance 100m/s², 3 times each in direction of X, Y and Z
Temperature characteristic ±2% F.S. of detected pressure (25℃)

*1 The display at the time of impressing negative pressure will be shown like below.

*2 Indicator accuracy is not guaranteed for the pressure range -0.1~0MPa.

*3 Air tube must be inserted into the atmospheric release port to maintain IP65. See below figure.

LCD dual displays equipped Pressure sensor spec.

Rated pressure range 0.000~1.000MPa
Proof pressure 1.5MPa
Fluid medium Air, non-corrosive / non-flammable gas
Power supply DC12V~24V(Ripple max. ±10%)
Current consumption 40mA or less (at No-loaded)
Switch output Switch output NPN open collector output/PNP open collector output
Switch output Max. load current 125mA
Switch output Max. supply voltage DC30V(NPN open collector output)/DC24V(PNP open collector output)
Switch output Residual voltage Max. 1.5V
Repeatability ±0.2% F.S. max. ±1 digit
Hysteresis One point setting mode Adjustable(*)
Hysteresis hysteresis mode Adjustable(*)
Hysteresis Wind comparator mode Adjustable(*)
Response time Max. 2.5ms (Malfunction protection function:Select from 25ms, 100ms, 250ms, 500ms, 1000ms, 1500ms)
Overload protection Equipped
Digital display 3 colors (Red, Green, Orange) indication (Sampling rate: 5 times / 1sec.)
Indication accuracy ±2% F.S. max. ±1 digit( at Ta=25±3℃)
Operation indicator Orange 1&2 indicator
Analog output(Voltage output) Output voltage:1~5V ±2.5% F.S. or less (within rated pressure range), Linearity:±1%F.S. or less, Output impedance :1kΩ
Environment proof Protective structure IP40
Environment proof Ambient temp. range Operation : 0~50℃, Storage : -10~60℃ (No dew condensation or freezing)
Environment proof Ambient humidity range Operation/Storage : 35~85%RH (No dew condensation)
Environment proof Voltage proof AC1000V 1 min. (Between the lead wire and the case)
Environment proof Insulation proof more than 50MΩ(DC500V)(Between the lead wire and the case)
Environment proof Vibration resistance Total amplitude 1.5mm or 100m/s² 10Hz-55Hz-10Hz scan for 1 min., two hours each direction of X, Y and Z.
Environment proof shock resistance 100m/s², 3 times each in direction of X, Y and Z
Temperature characteristics ±2% F.S or less (at 25℃, in temp. Range of 0~50℃)
Cable spec. Oil-resistance cable(0.15mm²)

*Hysteresis value is adjustable within 1~8 digits for one point set mode and window comparator mode.

Port size

Thread size

Taper pipe female thread Rc1/4, Rc3/8

Ordering Information

Detailed Safety Instructions

Caution

1.When the secondary side is released into the atmosphere, sympathetic vibration may occur due to the influence of the flow. Avoid prolonged use with the secondary side open to the atmosphere, as this may cause internal damage and other malfunctions.

2.Be sure to adjust the regulator in the direction of increasing pressure, and be sure to push the handle to lock it after adjusting the pressure.

3.Refer to the corresponding pages of precautions related to the dual-display digital pressure sensor and digital pressure gauge in the digital catalog.

4.Until the supply pressure rises to 0.05MPa for manual drain type and 0.15MPa for auto drain type, air will be discharged from the drain outlet, but this is not a malfunction.. At this timing, turning the drain knob will not stop the air flow. (If it takes a long time for the supply pressure to rise to 0.15MPa, please consult with PISCO.)

5.The drainage knob must be operated with the fingertips.

6.Use nylon tubing with an internal diameter of ø6 mm when piping tubing to the joint of the manual drain cock. The tube should not be bent immediately after the fitting.

7.The joint of the manual drain cock rotates freely and there is no need to remove the tube when draining manually.

Frequently Asked Questions for Air Preparation Series

Inquiries about this product

It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.

The following are frequently asked questions. Please check before making inquiries.