Pressure Sensor & Switch

Handy Manometer

RoHS2 Compliant

Thin, light weight and highly functional handy pressure gauge

Advantages

Thin, light weight and highly functional handy pressure gauge

Usability and convenience are pursued by palm top design.

Clear large display

3 & 1/2 digits LCD display

Three types of pressure range

Compound gauge pressure, compound gauge pressure (low range) and absolute pressure indication models are selectable depending on the applications.

Analog output function is equipped, too.

Low power consumption design

Using commercially available dry-cell batteries (AAA battery x 2 pcs.), last about 1000 hours.
(The Manometer does not come with batteries.)

Specifications

General spec.

Indication system 3 & 1/2 digits LCD
Sensor resolution 1 digit
Function Zero point adjustment (*1), Indication retention, Offset (*1), Auto-power-off
Operating temp. 0~50℃(No freezing)
Operating humidity 15~85%RH or below (No condensing)
Driving power 3VDC, 2 x AAA dry cell (*2)
Pressure port M5×0.8 Female thread
Protection structure IP40 (IEC standard) (*3)
Battery life About 1,000 hours

*1. GPH-B does not have the function of Zero point and Offset adjustment.

*2. The Manometer does not come with batteries. Use commercially available dry-cell batteries (alkaline or manganese cells).

*3. When with Analog output function, out of the standard spec.

Compound gauge pressure (low range) type

Rated pressure range -101~100kPa
Max. pressure 200kPa
Indicator accuracy (25℃) ±0.5% F.S. ±2 digits
Indicator accuracy (25±25℃) ±1% F.S.±2 digits or less
Admitted media Air, non-corrosive gas
Analog output power supply 5 ±0.5V DC, 5mA or less, External power supply (Built-in fuel cell is not possible.)
Analog output voltage -1.000~1.000V
Analog output accuracy ±10mV (Within indication standard)
Standard attachments Instruction manual, inspection report

Compound gauge pressure type specifications

Rated pressure range -100~1,000kPa
Max. pressure 1,500kPa
Indicator accuracy (25℃) ±0.5% F.S. ± 2 digits
Indication accuracy (25±25℃) ±1% F.S. ± 2 digits or less
Admitted media Air, non-corrosive gas
Analog output power supply 5 ±0.5V DC, 5mA or less, External power supply (Built-in fuel cell is not possible.)
Analog output voltage -0.100~1.000V
Analog output accuracy ±10mV (Within indication standard)
Standard attachments Instruction manual, inspection report

Absolute pressure type

Rated pressure range 0~100kPa abs
Max. pressure 200kPa abs
Indicator accuracy (25℃) ±0.5% F.S. ± 2digits
Indication accuracy(25±25℃) ±2% F.S. ±2digits or less
Admitted media Air, non-corrosive gas and fluids (SUS316 should not be corroded.)
Analog output power supply 5 ±0.5VDC, 5mA or less, External power supply (Built-in fuel cell is not possible.)
Analog output voltage 0.000~1.000V
Analog output accuracy ±10mV (Within indication standard)
Standard attachments Instruction manual, inspection report, Protective cover

* Liquid cannot be used when ø4 or ø6 straight push-in fitting (Code:4 or 6) is selected in port type and size. Please select a fitting with M5 male thread which can be used with your fluid from our fitting series.

Port size

Tube size

mm size (mm) φ4, φ6

Thread size

Metric female thread M5x0.8

Type & Price list

Detailed Safety Instructions

Warning

1.The product is not explosion-proof. Do not use in place where explosive-proof is required.

2.The product is not drip-proof and dust-proof.

3.The product is intended to measure target and does not have any control function for the purpose of accident prevention or other safety assurance.

Caution

1.The applicable media of GPH-V/-S are air and non-corrosive gas. Use with water or corrosive fluids may result in failure. The applicable medium of GPH-B is gas and liquid that do not corrode SUS316L. Use on corrosive media may cause injury or failure. Also, do not use flammable gas as it is not explosion-proof.

2.The measuring pressure should be within the specified pressure range. Applying more than the maximum pressure may cause a malfunction.

3.Be careful not to allow foreign matter to enter the pressure port. If any foreign matter gets inside, it may cause malfunction or air leakage. If there is a possibility of contamination, please use through a filter or similar.

4.Be careful of accidents caused by the strap. When using with the strap attached, intentionally swinging the product by holding the strap may result in an unexpected accident, injury, or damage to the product. When using the product, hold the main body firmly in your hand.

5.When tightening and fixing the push-in fitting to the pressure port, use a tightening torque of 1 to 1.5 N-m.

6.When using the analogue output function, applying voltage or signals to the CAL terminal due to mis-wiring of the connector, etc. may cause a malfunction. Also, be careful not to lose the battery compartment lid.

7.The protective cover is made of silicone rubber. Do not use in media that corrode the silicone rubber. The protective cover is also used to protect the unit from leaks when attaching and detaching fittings and tubes.

8.Perform regular maintenance and inspections. Before using the product, make sure that the product operates properly. Unexpected malfunction or failure of the product may result in the failure to display normal readings or to provide adequate functionality.

9.Use the specified battery. The use of non-specified batteries may cause malfunction.

10.The batteries must be inserted in the correct direction.Incorrect orientation of the battery may cause the battery to explode or leak, resulting in a malfunction or accident.When not in use for a long time, always remove the batteries and store them separately to prevent leakage.

11.Wipe off any stains on the product with a soft cloth. If the product gets dirty, wipe it off with a cloth soaked in neutral detergent diluted with water and wrung out well, then finish with a dry cloth. In that case, take care not to let the neutral detergent solution get into the pressure port or inside the unit. It may cause malfunction.

12.When storing the protective cover, keep it in a dark place at normal temperature and humidity. Prolonged exposure to ultraviolet rays may cause deterioration and discoloration.

Frequently Asked Questions for Pressure Sensor & Switch Series

Inquiries about this product

It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.

The following are frequently asked questions. Please check before making inquiries.