Pressure Sensor & Switch

Small Pressure Sensor 11

RoHS2 Compliant

Small sized sensor of 24.5mm length x 10mm width

  • No copper-based metallic material is used in flow paths
  • HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.

Advantages

Compact size Pressure Sensor

Small sized sensor of 24.5mm length x 10mm width

Use of an analog output type and display (SED-31 series) can make a separate display system.

Three types of pressure introduction configuration is prepared.

Stem, Male thread, and Union type are available.

3 types of pressure range and 6 types of output specification

3 pressure ranges; positive pressure range, negative pressure range, and compound pressure range and 2 output specifications; switch output and analog output making 6 different types of output specifications

Copper alloy free material and against low ozone concentration on the air flow path.

Metal parts material is non-copper metals. HNBR for seal rubber material.

Specifications

General spec.

Fluid medium Air, non-corrosive/non-flammable gas
Pressure detection Diffused metaloxide semiconductive pressure transduce, Gauge pressure
Power supply 10.8~30VDC (Including Ripple)
Current consumption 20mA or less (No-load at 24VDC)
Storage temp. range -20~70°C (Atmospheric pressure, Humidity:60% RH or less)
Operating temperature range 0~60°C (No freezing)
Operating humidity range 35~85% RH (No dew condensation)
Protective structure IEC standard IP40 equiv.

Negative pressure type specifications

Operating pressure range -100~0kPa
Proof pressure 200kPa

Compound pressure type specifications

Operating pressure range -100 ~ 300kPa
Proof pressure 1MPa

Positive pressure type specifications

Operating pressure range 0~1.0MPa
Proof pressure 1.5MPa

Switch output type Switch specifications

No. of pressure setting 1
Switch output NPN open collector/30V 80mA or less (Residual voltage: 0.8V or less)
Operation indicator N.O. (Red LED turns on when pressure is above the setting.)
Hysteresis Fixed (2% F.S. or less)
Operating accuracy ±3% F.S. or less (at Ta=25℃)
Response time About 1msec
Pressure setting range Positive type:0~1.0MPa/Nagative type:-100~ 0kPa/Conpoumd type:-100~300kPa

Analog Output Type Analog Output specifications

Output voltage 1~5V
Zero-point voltage 1 ±0.1V
Voltage at setting pressure 5 ±0.1V (at -100kPa)
Output current 1mA or less (Load resistance:5kΩ)
Temperature characteristics ±2%F.S.or less (at Ta=25°C)
Linearity ±0.5% F.S. or less (at Ta=25°C)

Port size

Tube size

mm size (mm) φ4, φ6

Applicable tube fitting size

mm size (mm) φ4, φ6

Thread size

Metric male thread M5x0.8
Taper pipe male thread R1/8

Circuit Diagram

Type & Price list

Detailed Safety Instructions

Caution

1.When adjusting the pressure of the 11 series sensor with switch output, use the small screwdriver supplied and turn gently without excessive force. Applying excessive force may cause damage to the product.

2.For the sensor head of the display unit (SED-31), use type VUS11...A, VUS12...A or SEU11...A. If the specifications of the sensor head are different, the display accuracy may not meet the specifications.

3.If other devices are connected to the same power supply as this sensor, and the SW output terminal is short-circuited with minus (-) terminal by a load operation test switch or the like while the minus (-) terminal (COM) is disconnected, the reverse current will flow to switch output circuit and the sensor will be damaged. When using this type of circuit, install a diode to prevent reverse current on the minus (-) side power supply line or on the SW output line in the direction shown in the following figure.

4.When setting the pressure and differential response, use a small screwdriver and gently turn the trimmer within its rotation range without applying excessive force. Applying excessive force may cause damage to the trimmer and to the circuit board.

5.Precautions for mounting the main unit (Thread type small pressure sensor 11 & 12 series) (1) Tighten the thread using the hexagonal-column of the main unit with an appropriate tool. (2) When tightening the threaded body, refer to the tightening torque in the table blow and the allowable torque of the tool. Failure to tighten the threaded body with proper torque may result in damage to the product or tool, loosening of the thread, or leakage.

6.Precautions for removing the main unit (Thread type small pressure sensor 11 & 12 series) (1) Remove the main unit by using the hexagonal-column of the main unit and using an appropriate tool. (2) Remove the sealant or a foreign substance on the removed mating thread. If the sealant adheres to the peripheral device, it may get into the devices and cause a malfunction.

7.Since the sensor head connector ACPG-31-CN1 is a crimp terminal, it is not necessary to remove the lead wire insulation when wiring. Wiring with the insulation removed may result in a short circuit.

Frequently Asked Questions for Pressure Sensor & Switch Series

Inquiries about this product

It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.

The following are frequently asked questions. Please check before making inquiries.