Pressure Sensor & Switch

Small Pressure Sensor 12

RoHS2 Compliant

Small sized sensor of 25.4mm length x 8.5mm width

  • No copper-based metallic material is used in flow paths
  • HNBR or FKM is used for the seal rubber material. *Some products are only compatible in the flow path.

Advantages

Compact size sensor. Connecter type lead-wire contributes to easy wiring and maintenance.

Small sized sensor: 25.4mm length x 8.5mm width

Use of an analog output type and display (SED-31 series) can make a separate display system.

Use of an analog output type and display (SED-31 series) can make
a separate display system.

Three types of pressure introduction configuration is prepared.

Switch output and analog output type for output spec.

Connector type lead wire

Easy wiring and maintenance.

5 types of lead wire length are available.

Select from 500mm, 1000mm, 2000mm, 3000mm and 5000mm according to your installation site.

Copper alloy free material and against low ozone concentration on the air flow path.

Specifications

General spec.

Fluid medium Air, non-corrosive/non-flammable gas
Pressure detection Diffused metaloxide semiconductive pressure transducer, Gauge pressure
Power supply 10.8~30VDC (Including Ripple)
Current consumption 20mA or less (No-load at 24VDC)
Operating pressure range -100~0kPa
Proof pressure 1MPa
Storage temp. range -20~70°C
Operating temperature range 0~60°C (No freezing)
Operating humidity range 30 ~85% RH (No dew condensation)
Protective structure IEC standard IP40 equiv.

Switch output type Switch specifications

No. of pressure setting 1
Switch output NPN open collector/30V 80mA or less (Residual voltage:0.8V or less)
Operation indicator N.O. (Red LED turns on when pressure is above the setting.)
Hysteresis Fixed (2% F.S. or less)
Operating accuracy ±3% F.S. or less (at Ta=25°C)
Response About 1msec
Pressure setting range -100~0kPa

Analog output type Analog output specifications

Output voltage 1~5V
Zero-point voltage 1±0.04V
Voltage at setting pressure 4.6 ±0.04V (at -90kPa)
Output current 0.495mA or less (Load resistance:10kΩ)
Temp. characteristics ±2% F.S. or less (at Ta=25°C)
Linearity ±0.5% F.S.or less (at Ta=25°C)
Output impedance 1kΩ

Port size

Tube size

mm size (mm) φ4, φ6

Applicable tube fitting size

mm size (mm) φ4, φ6

Thread size

Metric male thread M5x0.8
Taper pipe male thread R1/8

Circuit Diagram

Ordering Information

Detailed Safety Instructions

Caution

1.For the sensor head of the display unit (SED-31), use type VUS11...A, VUS12...A or SEU11...A. If the specifications of the sensor head are different, the display accuracy may not meet the specifications.

2.When adjusting the pressure of the 12 series sensors with switch output, refer to the following figure and use the supplied small screwdriver to gently turn the sensor without applying excessive force.

3.If other devices are connected to the same power supply as this sensor, and the SW output terminal is short-circuited with minus (-) terminal by a load operation test switch or the like while the minus (-) terminal (COM) is disconnected, the reverse current will flow to switch output circuit and the sensor will be damaged. When using this type of circuit, install a diode to prevent reverse current on the minus (-) side power supply line or on the SW output line in the direction shown in the Fig. 2.

4.When setting the pressure and differential response, use a small screwdriver and gently turn the trimmer within its rotation range without applying excessive force. Applying excessive force may cause damage to the trimmer and to the circuit board.

5.Precautions for mounting the main unit (Thread type small pressure sensor 11 & 12 series) (1) Tighten the thread using the hexagonal-column of the main unit with an appropriate tool. (2) When tightening the threaded body, refer to the tightening torque in the table blow and the allowable torque of the tool. Failure to tighten the threaded body with proper torque may result in damage to the product or tool, loosening of the thread, or leakage.

6.Precautions for removing the main unit (Thread type small pressure sensor 11 & 12 series) (1) Remove the main unit by using the hexagonal-column of the main unit and using an appropriate tool. (2) Remove the sealant or a foreign substance on the removed mating thread. If the sealant adheres to the peripheral device, it may get into the devices and cause a malfunction.

7.Since the sensor head connector ACPG-31-CN1 is a crimp terminal, it is not necessary to remove the lead wire insulation when wiring. Wiring with the insulation removed may result in a short circuit.