Pressure Sensor & Switch

Small Pressure Sensor 11&12-series, Indicator for Analog output type

RoHS2 Compliant

With use of small Pressure Sensor, a separate display system become possible.

Advantages

With use of small Pressure Sensor, a separate display system become possible.

30㎜ indicator of good visibility with LCD 3-color dual-display

2-color indication on Main display
Main display: Pressure value (Red or Green)
Sub display: Setting value (Orange)

Compact body size

Body size: 30mm width & 30mm height

Power consumption is 40mA.

SED-30:50mA⇒SED-31:40mA

Connection by Connector cable to the display unit. Easy attachment and detachment.

Lock function is built-in

Wrong output by misoperation can be prevented by locking function.
Key icon is displayed in operating mode.

Specifications

General spec.

Power supply 12-24VDC (Ripple ±10% or less)
Current consumption 40mA or less (No-load)
Sensor input voltage 1~5V
Switch output (NPN open collector output) NPN 2 points output:Max. load current:125mA, Max. supply voltage:30VDC, Internal voltage drop:1.5V or less
Switch output (PNP open collector output) PNP 2 points output:Max. load current:125mA, Max. supply voltage:24VDC, Internal voltage drop:1.5V or less
Repetitiveness ±0.1%F.S. ±1digit or less
Hysteresis One point setting mode, Hysteresis mode, Wind comparator mode:Adjustable (*1,*2)
Response time 2.5ms or less (Malfunction protection function:Selection from 25ms, 100ms, 250ms, 500ms, 1000ms, 1500ms)
Output Short circuit protection Equipped
Digital display Main display:2 colors (Red and Green)
Indication accuracy ±1%F.S. ±1digit or less (at Ta=25±3℃)
Operation indicator Orange 1& 2 indicator
Analog output Output voltage:1~ 5V ±2% F.S. or less (within rated pressure range) Linearity:±1%F.S.or less, Output impedance:1kΩ
Protective structure IP40
Ambient temp. range At operation:0~50℃, At storing:-10~60℃ (No dew condensation, and no freezing)
Ambient hum. range At operation or storing:35~85% RH (No dew condensation)
Voltage proof 1000VAC 1min. (Between the lead wire and the case)
Insulation proof 50MΩ or more (500VDC) (Between the lead wire and the case)
Vibration proof Double application 1.5mm or 100m/s2, 1min. 10~55~10 Hz, X, Y, Z each direction 2 hours
Shock proof 100m/s2 X, Y, Z each direction 3 times
Temperature characteristics ±0.5%F.S. or less (at Ta=25℃, Range:0 ~+50℃)

* Hysteresis is adjustable (1~8 digits) in One point setting mode and Wind comparator mode.

Negative pressure type specifications

Sensor type setting (*1) C-2
Rated pressure range (Sensor head) -100~0kPa
Applicable sensor head VUS11-□A,VUS12-□A

* Select C-1, C-2 or C-3 in the sensor type setting mode. (For details, refer to the instruction manuals.)

Compound pressure type specifications

Sensor type setting (*1) C-1
Rated pressure range (Sensor head) -100~300kPa
Applicable sensor head VUS11-□AR

* Select C-1, C-2 or C-3 in the sensor type setting mode. (For details, refer to the instruction manuals.)

Positive pressure type specifications

Sensor type setting (*1) C-3
Rated pressure range (Sensor head) 0~1MPa
Applicable sensor head SEU11-□A

* Select C-1, C-2 or C-3 in the sensor type setting mode. (For details, refer to the instruction manuals.)

Circuit Diagram

Type & Price list

Option & Maintenance items

Small Pressure Sensor 11&12-series, Indicator for Analog output typeWall bracket (Display Accessories )

Wall bracket for Indicator for Small Pressure Sensor 11 & 12.

Small Pressure Sensor 11&12-series, Indicator for Analog output typeUpright bracket (Display Accessories)

Upright bracket for Indicator for Small Pressure Sensor 11 & 12.

Digital Pressure Sensor 31& 32 Series with 3-color dual displayPanel adapter set

Panel adaptor set for Digital Pressure Sensor 31 & 32 with LCD dual displays with 3-colors and Indicator for Small Pressure Sensor 11 & 12.

Small Pressure Sensor 11&12-series, Indicator for Analog output typeConnector for sensor head (Display Accessories)

Connector for sensor head of Indicator for Small Pressure Sensor 11 & 12.

Digital Pressure Sensor 31& 32 Series with 3-color dual displayPanel adapter set with front cover

Panel adapter set with front protective cover for Digital Pressure Sensor 31 & 32 with LCD dual displays with 3-colors and Indicator for Small Pressure Sensor 11 & 12.

Detailed Safety Instructions

Warning

1.Incorrect wiring may cause damage, malfunction, or malfunction of the sensor.

Caution

1.For the sensor head of the display unit (SED-31), use type VUS11...A, VUS12...A or SEU11...A. If the specifications of the sensor head are different, the display accuracy may not meet the specifications.

Frequently Asked Questions for Pressure Sensor & Switch Series

Inquiries about this product

It is also possible to suggest products suitable for various conditions such as applications and functions. Please feel free to contact us or visit the nearest sales office.

The following are frequently asked questions. Please check before making inquiries.